Description
Specifications
Rated Power: 6KW
Battery Compatibility: Lead-acid and Lithium
Max Charge/Discharge Current: 135A
Surge Power Backup: 200% surge capability
Generator Mode: Supports automatic generator On/Off control
Connection Type: Supports both single-phase and three-phase connections, up to 36 kW in parallel
Operating Mode: Self-use and Generator mode with peak shaving control
Model Year: 2025
Specifications:
Models 6K
Input DC (PV side)
Recommended max. PV array size 12 kW
Max. usable PV input power 9.6 kW
Max. input voltage 500 V
Rated voltage 330 V
Start-up voltage 90 V
MPPT voltage range 90 - 435 V
Max. input current 16 A / 16 A
Max. short circuit current 20 A / 20 A
MPPT number / Max. input strings number 2 / 2
Battery
Battery type Li-ion / Lead-acid
Battery voltage range 40 - 60 V
Max. charge / discharge power 6 kW
Max. charge / discharge current 135 A
Communication CAN / RS485
Output AC (Grid side)
Rated output power 6 kW
Max. apparent output power 6 kVA
Operation phase L/N/PE
Rated grid voltage 220 V / 230 V
Rated grid frequency 50 Hz / 60 Hz
Rated grid output current 27.3 A / 26.1 A
Max. output current 27.3 A / 26.1 A
Power factor > 0.99 (0.8 leading - 0.8 lagging)
THDi < 2%
Input AC (Grid side)
Input voltage range 187 - 253 V
Max. input current 40 A
Frequency range 45 - 55 Hz / 55 - 65 Hz
Output AC (Back-up)
Rated output power 6 kW
Max. apparent output power 2 times of rated power, 10 s
Back-up switch time < 4 ms
Rated output voltage L/N/PE, 220 V / 230 V
Rated frequency 50 Hz / 60 Hz
Rated output current 27.3 A / 26.1 A
Max. AC passthrough current 40 A
THDv (@linear load) < 2%
Efficiency
Max. efficiency 96.2%
EU efficiency 96.1%
BAT charged by PV / AC max. efficiency 95.3% / 93.9%
BAT discharged to AC max. efficiency 93.8%
Protection
Ground fault monitoring Yes
DC reverse-polarity protection Yes
Integrated AFCI 2.0 Optional
Protection class / Over voltage category I / II (PV and BAT), III (MAINS and BACKUP and GEN)
General Data
Dimensions (W × H × D) 335 × 560 × 253 mm
Weight 23.5 kg
Topology High frequency isolation (for battery)
Operating ambient temperature range -40 ~ + 60°C
Ingress protection IP66
Cooling concept Intelligent fan-cooling
Max. operation altitude 3000 m
Grid connection standard NRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA, NBR 16149, NBR 16150
Safety / EMC standard IEC/EN 62109-1/-2, EN 61000-6-2/-3
Features
DC connection MC4 plug (PV port) / Terminal Block (BAT port)
AC connection Terminal Block
Display 7.0" LCD display & Bluetooth + APP