Description
The Fluke 376 FC is part of the Fluke Connect family of wireless test tools. Now you can:
Log and trend measurements to pinpoint intermittent faults
Transmit results wirelessly via Fluke Connect® Measurements app
Create and send reports right from the field
Stay safely away from the arc flash zone through Bluetooth connectivity to Apple and Android devices
The Fluke 376 FC is the direct replacement for the Fluke 376 Clamp Meter.
Connect your meter to your smartphone with Fluke Connect Measurements
Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks
Record results directly to your phone and the Cloud
Capture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC
Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls
iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)
TPAK magnetic hanging strap (included)
Integrated VFD low pass filter for accurate motor drive measurements
Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
CAT IV 600 V, CAT III 1000 V safety rating
Three-year warranty
Soft carrying case
Measurement Capability
1000 A ac and dc current measurement
2500 A ac current measurement with iFlex flexible current probe
1000 V ac and dc voltage measurement
True-rms voltage and current for accurate measurements on non-linear signals
Frequency measurement to 500 Hz with body jaw and iFlex
Resistance measurement to 60 kΩ with continuity detection
Min, max, average, and inrush recording to capture variations automatically
500 mV dc measurement range to interface with other accessories
1000 μF capacitance measurement
General Specifications
AC Current via Jaw
Range 999.9 A
Resolution 0.1 A
Accuracy 2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (View phone number) Hz)
Crest Factor (50 Hz/60 Hz) 3 @ 500 A
2.5 @ 600 A
Add 2% for C. F. >;;;;;;;;;;;;;;2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C. F. >;;;;;;;;;;;;;; 2
Position Sensitivity
Flexible current probe
i(View phone number) Flex i(View phone number) Flex
A
Distance from Optimum 0.5 in (12.7 mm) 1.4 in (35.6 mm)
Error ±0.5 % ±0.5 %
B
Distance from Optimum 0.8 in (20.3 mm) 2.0 in (50.8 mm)
Error ±1.0 % ±1.0 %
C
Distance from Optimum 1.4 in (35.6 mm) 2.5 in (63.5 mm)
Error ±2.0 % ±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 600.0 A
Resolution 0.1 A
Accuracy 2% ±5 digits
AC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1.5% ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1% ±5 digits
mV dc
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1% ±5 digits
Frequency via Jaw
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Resistance
Range 60 kΩ
Resolution 0.1 Ω (≤600 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60 kΩ)
Accuracy 1% ±5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ±4 digits
Mechanical Specifications
Maximum voltage between any terminal and earth ground 1000 V
Batteries 2 AA, NEDA 15A, IEC LR6
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity -
non-condensing (<;;;;;;;;;;;;;; 10°C) ≤90% RH (at 10 °C to 30 °C)