All categoriesDropdown arrow
1 / 1
Rs 115,000

Fluke 376FC Price In Pakistan | Fluke Clamp Meter In Pakistan

Brandreth Road, Lahore
1 week ago
Details
ConditionNew
Description
The Fluke 376 FC is part of the Fluke Connect family of wireless test tools. Now you can: Log and trend measurements to pinpoint intermittent faults Transmit results wirelessly via Fluke Connect® Measurements app Create and send reports right from the field Stay safely away from the arc flash zone through Bluetooth connectivity to Apple and Android devices The Fluke 376 FC is the direct replacement for the Fluke 376 Clamp Meter. Connect your meter to your smartphone with Fluke Connect Measurements Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks Record results directly to your phone and the Cloud Capture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included) TPAK magnetic hanging strap (included) Integrated VFD low pass filter for accurate motor drive measurements Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it CAT IV 600 V, CAT III 1000 V safety rating Three-year warranty Soft carrying case Measurement Capability 1000 A ac and dc current measurement 2500 A ac current measurement with iFlex flexible current probe 1000 V ac and dc voltage measurement True-rms voltage and current for accurate measurements on non-linear signals Frequency measurement to 500 Hz with body jaw and iFlex Resistance measurement to 60 kΩ with continuity detection Min, max, average, and inrush recording to capture variations automatically 500 mV dc measurement range to interface with other accessories 1000 μF capacitance measurement General Specifications AC Current via Jaw Range 999.9 A Resolution 0.1 A Accuracy 2% ±5 digits (10 Hz to 100 Hz) 2.5% ±5 digits (View phone number) Hz) Crest Factor (50 Hz/60 Hz) 3 @ 500 A 2.5 @ 600 A Add 2% for C. F. >;;;;;;;;;;;;;;2 AC Current via Flexible Current Probe Range 2500 A Resolution 0.1 A (≤ 600 A) 1 A (≤ 2500 A) Accuracy 3% ±5 digits (5 – 500 Hz) Crest Factor (50/60Hz) 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C. F. >;;;;;;;;;;;;;; 2 Position Sensitivity Flexible current probe i(View phone number) Flex i(View phone number) Flex A Distance from Optimum 0.5 in (12.7 mm) 1.4 in (35.6 mm) Error ±0.5 % ±0.5 % B Distance from Optimum 0.8 in (20.3 mm) 2.0 in (50.8 mm) Error ±1.0 % ±1.0 % C Distance from Optimum 1.4 in (35.6 mm) 2.5 in (63.5 mm) Error ±2.0 % ±2.0 % Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. DC Current Range 600.0 A Resolution 0.1 A Accuracy 2% ±5 digits AC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1.5% ±5 digits (20 Hz to 500 Hz) DC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1% ±5 digits mV dc Range 500.0 mV Resolution 0.1 mV Accuracy 1% ±5 digits Frequency via Jaw Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ±5 digits Trigger level 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥5 A 100 Hz to 500 Hz, ≥10 A Frequency via Flexible Current Probe Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ±5 digits Trigger level 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz, ≥25 A Resistance Range 60 kΩ Resolution 0.1 Ω (≤600 Ω) 1 Ω (≤6000 Ω) 10 Ω (≤60 kΩ) Accuracy 1% ±5 digits Capacitance Range 1000 μF Resolution 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) Accuracy 1% ±4 digits Mechanical Specifications Maximum voltage between any terminal and earth ground 1000 V Batteries 2 AA, NEDA 15A, IEC LR6 Operating temperature -10 °C to +50 °C Storage temperature -40 °C to +60 °C Operating humidity - non-condensing (<;;;;;;;;;;;;;; 10°C) ≤90% RH (at 10 °C to 30 °C) ≤75% RH (at 30 °C to 40 °C)
Related ads
Location
Pakistan
Ad id 1089608233
Report this ad