All categoriesDropdown arrow
Tailor Services
Fluke 355 True RMS Clamp Meter In Pakistan | Fluke 355 In Pakistan 0
1 / 2
Rs 210,000

Fluke 355 True RMS Clamp Meter In Pakistan | Fluke 355 In Pakistan

Gulshan-e-Iqbal, Karachi
1 week ago
Details
ConditionNew
Description
Product overview: Fluke 355 True RMS 2000 A Clamp Meter Versatile and rugged tools for applications with high currents Confidently take reliable readings with the True RMS, Fluke 355 digital clamp meter the tool of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements. Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians. Specifications: Fluke 355 True RMS 2000 A Clamp Meter Electrical Specifications Current measurement DC and AC 10 Hz to 100 Hz Range 40 A / 400 A / 2000 A / 1400 AC rms Resolution 10 mA / 100 mA / 1 A Accuracy A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits Trigger level for Inrush 0.50 A / 5.0 A / 5 A Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A Crest Factor (50/60 Hz) Range 40 A / 400 A / 2000 A / 1400 AC rms Crest Factor1 2 @ 33 A, 2.4 @ 27 A 2 @ 330 A, 2.4 @ 270 A 2 @ 1000 A, 2.4 @ 833 A Current measurement AC 100.1 Hz to 1 kHz Range 40 A / 400 A / 2000 A; 1400 AC rms Resolution 10 mA / 100 mA / 1 A Accuracy 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits Trigger level for Inrush 0.50 A / 5.0 A / 5 A Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A Voltage measurement DC and AC 10 Hz to 100 Hz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively. ) Range 4 V / 40 V / 400 V / 600 V AC rms / 1000 VDC Resolution 1 mV / 10 mV / 100 mV / 1 V Accuracy 1% rdg + 10 digits 1% rdg + 5 digits Trigger level for Hz filter OFF 0.25 V / 6 V Trigger level for Hz filter ON 0.25 V / 6 V Voltage measurement AC 100.1 Hz to 1 kHz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively. ) Range 4 V / 40 V / 400 V / 600 V ac rms Resolution 1 mV / 10 mV / 100 mV / 1 V Accuracy 3% rdg + 10 digits 3% rdg + 5 digits Trigger level for Hz filter OFF 0.050 V / 0.25 V / 6 V Trigger level for Hz filter ON 0.050 V / 0.25 V / 6 V Ohms measurement Range 4 kΩ / 40 kΩ / 400 kΩ Resolution 0.1 Ω / 1 Ω / 10 Ω / 100 Ω Accuracy 1.5% + 5 digits Continuity beeper On at ≤ 30 Ω Off at ≥ 100 Ω Frequency measurement Measurement range 5.0 Hz to 1 kHz Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) Accuracy – 5.0 Hz to 100 Hz 0.2% + 2 counts Accuracy – 100.1 Hz to 1 kHz 0.5% + 5 counts Trigger level Refer to current and voltage tables
Related ads
Location
Pakistan
Ad id 1092500840
Report this ad