Description
Features:
600 V Cat III safety rating
50% bigger display with bright white backlight
Over-voltage indicator
Frequency and temperature measurement
Voltage, resistance, continuity, capacitance
Input terminal for ac and dc current measurements to 10 A current
Diode test, data hold
Accuracy Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).
Function Range Resolution Accuracy
AC volts
(40 Hz to 500Hz)1 4.000 V
40.00 V
400.0 V
1000 V 0.001 V
0.01 V
0.1 V
1 V 1.0 % + 3
DC volts 4.000 V
40.00 V
400.0 V
1000 V 0.001 V
0.01 V
0.1 V
1 V 0.5 % + 3
AC millivolts 400.0 mV 0.1 mV 3.0 % + 3
DC millivolts 400.0 mV 0.1 mV 1.0 % + 10
Diode test2 2.000 V 0.001 V 10%
Resistance
(Ohms) 400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ 0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ 0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
Capacitance3 40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF 0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF 2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency1
Hz
(10 Hz – 100 kHz) 50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz 0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz 0.1 % + 3
Duty Cycle1 1 % to 99 % 0.1 % 1 % typical 4
AC current μA
(40 Hz to 400 Hz) 400.0 μA
4000 μA 0.1 μA
1 μA 1.5 % + 3
AC current mA
(40 Hz to 400 Hz) 40.00 mA
400.0 mA 0.01 mA
0.1 mA 1.5 % + 3
AC current A
(40 Hz to 400 Hz) 4.000 A
10.00 A 0.001 A
0.01 A 1.5 % + 3
DC current μA 400.0 μA
4000 μA 0.1 μA
1 μA 1.5 % + 3
DC current mA 40.00 mA
400.0 mA 0.01 mA
0.1 mA 1.5 % + 3
DC current A 4.000 A
10.00 A 0.001 A
0.01 A 1.5 % + 3
Temperature 50 °C- 400 °C
0 °C- 50 °C
-55 °C- 0 °C 0.1C 2 % ± 1 °C
± 2 °C
9 % ± 2 °C
Backlight - - Yes