Description
HW-300PRO Coating Thickness Gauge
Material: ABS
Product size: 122MM*50MM*22MM
Power supply: 2 1.5V AAA batteries (battery not included)
Probe: F probe, N probe
Magnetic induction: Measuring principle(F), Eddy current effect(N)
Measuring range: 0-2000UM
Measurement accuracy: ±(3% 1UM)
Operating temperature: -10°C~50°C
Accessories: Thickness Gauge 1PCS Manual Calibration Sheet
feature:
Ultra-precision resolution 1um, FE/NFE coating measurement, automotive paint 0-2000um
Small size and high precision
battery level indicator
Automatic shutdown function
for FE/NFE
Measurement step
Step 1. Prepare the parts to be tested.
Step 2. Stay away from the metal object at least 2 cm, press the switch key to turn on.
Note: it is suggested that the instrument should be zeroed with reference to "zero calibration" before
testing.
Step 3. The probe is placed vertically and quickly on the surface to be measured until the drop is heard,
and the measured value is displayed on the screen, and then the probe is lifted at least 2 cm away from
the part to be measured, and the next measurement can be carried out.
Note: if the automatic shutdown function is turned on and there is no operation within 3 minutes, the
instrument will automatically shut down