All categoriesDropdown arrow
Tailor Services
Deye 12kw 3phase Hybrid Solar inverter 0
1 / 4
Rs 900,000

Deye 12kw 3phase Hybrid Solar inverter

Satellite Town, Rawalpindi
1 week ago
Details
Is DeliverableNo
TypeHybrid Inverter
KilowattOthers
BrandInverex
Price900,000
ConditionNew
Description
Deye SUN-12K-SG05LP3-EU hybrid Solar inverter. Deye is the real brand name of inverex nitrox. Model SUN-12K-SG04LP3-EU Battery Input Data Battery Type Lead-acid or Lithium-ion Battery Voltage Range(V) 40-60 Max. Charging Current(A) 120 150 190 210 240 Max. Discharging Current(A) 120 150 190 210 240 Charging Strategy for Li-ion Battery Self-adaption to BMS Number of battery input 1 PV String Input Data Max PV Input PowerW 15600 MaxPV Input VoltageV 800 Start-up VoltageV 160 MPPT Voltage RangeV (View phone number) Rated PV Input Voltage(V) 550 Max. Operating PV Input Current (A) 13+13 26+13 Max. Input Short-Circuit Current (A) 17+17 34+17 No. of MPP Trackers/No. of String Per MPP Tracker 2/1+1 2/2+1 AC Input/Output Data Rated AC Input/Output Active PowerW12000 Max AC Input/Output Apparent Power VA13200 Peak Power (off-grid)W 2 times of rated power, 10s Rated AC Input/Output CurrentA18.2/17.4 Max AC Input/Output CurrentA 8.4/8 10/9.6 13.4/12.8 16.7/15.9 20/19.1 Max. Three-phase Unbalanced Output CurrentA 11.4/10.9 13.6/13 18.2/17.4 22.7/21.7 27.3/26.1 Max Continuous AC Passthrough (grid to load)A 45 Rated Input/Output Voltage/Range(V) 220/380V230/400V 0.85Un-1.1Un Grid Connection Form 3L+N+PE Rated Input/Output Grid Frequency/Range 50/45-55, 60/55-65 Power Factor Adjustment Range 0.8 leading to 0.8 lagging Total Current Harmonic Distortion THDi <3% (of nominal power) DC Injection Current <0.5%ln Efficiency Max Efficiency 97.6% Euro Efficiency 97.0% MPPT Efficiency 99% Equipment Protection DC Polarity Reverse Connection Protection YES AC Output Overcurrent Protection YES AC Output Overvoltage Protection YES AC Output Short Circuit Protection YES Thermal Protection YES DC Terminal Insulation Impedance Monitoring YES DC Component Monitoring YES Ground Fault Current Monitoring YES Power Network Monitoring YES Island Protection Monitoring YES Earth Fault Detection YES DC Input Switch YES Overvoltage Load Drop Protection YES Residual Current (RCD) Detection YES Surge Protection Level TYPE II(DC), TYPE II(AC) Interface Communication Interface RS485/RS232/CAN Monitor Mode GPRS/WIFI/Bluetooth/4G/LAN(optional) General Data Operating Temperature Range -40 to +60℃, >45℃ Derating Permissible Ambient Humidity 0-100% Permissible Altitude 2000m Noise ≤ 55 dB(A) Ingress Protection(IP) Rating IP 65 Inverter Topology Non-Isolated Over Voltage Category OVC II(DC),OVC III(AC) Cabinet sizeW*H*D[mm] 422×658×254 Excluding connectors and brackets Weight[kg] 38 Warranty 5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy Type Of Cooling Intelligent air cooling Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE (View phone number), OVE-Richtlinie R25, G99, VDE-AR-N 4105 Safety EMC/Standard contact whatsapp 0 3 3 6 5 1 6 4 7 8 0
Related ads
Location
Pakistan
Ad id 1089040792
Report this ad