Description
Features:AS850 Smart Sensor
Overview:
Measuring range: 1.2 to 225mm (steel);
Accuracy: ±(1%H+0.1)mm; Resolution: (<;;;;100mm)
0.1mm; Frequency : 5MHZ;Sound velocity range: 1000 to 9999m/s; Sensor Operation
temperature : Normal 0-60c High tem 0-250c (with high tem agent ); 10 Data store/recall
function; Automatic zero reset ;Auto Power Off ;Low battery indication Function; Power :
1.5V AAA*3 Batteries(not include)
Features & Functions:
1. Auto calibration to assure the accuracy.
2. Auto linear compensation: this advanced software program enhances the precision by correcting the non-linear accuracy of transducer.
3. Make a quick adjustment for the sound velocity / thickness, and a quick recall to the stored data
4. Coupling status indication: Observing the coupling icon to learn if the coupling is accomplished or not.
5.10 thickness measurement storage and recall function available, which facilitates the height work or working in wild area.
6. Sound velocity measurement.
7.12 sound velocity for different material which is also adjustable .
8. More than 10000 times long life keys.
9. Largr LCD display for easy readout.
10. Low battery indication and auto power off.
11. The unit has a unique memory that retains all of its settings even when the power is off.
Specifications:
Measuring Range: 1.2~220mm(steel)
Accuracy: ±(1%H+0.1)mm,
Working frequency: 5MHz
Minimum display unit: 0.1 mm
Mininum limit for tube measuring(steel): 20 * 3.0mm(steel)
Sound velocity Range: 1000~9999m/s
General Characteristics:
Operation temperature/humidity: 0 to 40°C, 90%RH
Power supply: 3 * 1.5V AAA alkaline batteries (not included)
Item Size: 70*145*28mm
Item Weight: 210g
The usage of an ultrasonic thickness gauge for non-destructive testing to check material properties such as thickness measurement, is now regularly utilized in all areas of industrial measurements. The ability to gauge thickness measurement without requiring access to both sides of the test piece, offers this technology a multitude of possible applications.
Specifications:
Measuring Range
1.2~220mm
Accuracy
±(1%H+0.1)mm
Resolution (<;;;;100mm)0.1mm
Sound Velocity Range
1000~9999m/s
Frequency 5MHz
Operation Temperature 0C~45C
Sensor Operation
Temperature
Normal 0~60C High Tem0~250C
(with high temp. Agent)
Minimum limit for tube
measuring
10mm probe:20*3mm(steel)
Data Store/Recall Function
yes
Sound Velocity Measuring yes
LCD Backlight Display yes
Alarm Setup no
Low Battery Indication yes
Auto Power Off: yes
Power supply: 3 * 1.5V AAA alkaline batteries